ARE4E(X) 0,6/1kV / Eca

Products

ARE4E 0,6/1kV 1x150 IT

Nexans ref. 10548246

  • With smaller neutral conductor: No
  • Neutral Type:
  • Lay Up: Single core
  • Number of cores: 1
  • Number of phases: -
  • Conductor cross-section: 150 mm²
  • Phase Conductor Cross Section: - mm²
  • Neutral conductor section (when smaller): - mm²
  • Conductor diameter: 14.3 mm
  • Phase Conductor Diameter: - mm
  • Neutral Conductor Diameter: - mm
  • Average insulation thickness: 1.4 mm
  • Insulation thickness of neutral conductor: - mm
  • Average sheath thickness: 1.4 mm
  • Nominal outer diameter: 21.6 mm
  • Nominal overall diameter of each phase cable: - mm
  • Nominal overall diameter: - mm
  • Approximate weight: 560 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
  • Permissible short circuit current conductor 1s: 14.1 kA

 

ARE4E 0,6/1kV 1x240 IT

Nexans ref. 10548247

  • With smaller neutral conductor: No
  • Neutral Type:
  • Lay Up: Single core
  • Number of cores: 1
  • Number of phases: -
  • Conductor cross-section: 240 mm²
  • Phase Conductor Cross Section: - mm²
  • Neutral conductor section (when smaller): - mm²
  • Conductor diameter: 18.5 mm
  • Phase Conductor Diameter: - mm
  • Neutral Conductor Diameter: - mm
  • Average insulation thickness: 1.7 mm
  • Insulation thickness of neutral conductor: - mm
  • Average sheath thickness: 1.5 mm
  • Nominal outer diameter: 26.9 mm
  • Nominal overall diameter of each phase cable: - mm
  • Nominal overall diameter: - mm
  • Approximate weight: 880 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
  • Permissible short circuit current conductor 1s: 22.7 kA

 

ARE4E 0,6/1kV 1x25 IT

Nexans ref. 10548228

  • With smaller neutral conductor: No
  • Neutral Type:
  • Lay Up: Single core
  • Number of cores: 1
  • Number of phases: -
  • Conductor cross-section: 25 mm²
  • Phase Conductor Cross Section: - mm²
  • Neutral conductor section (when smaller): - mm²
  • Conductor diameter: 6.0 mm
  • Phase Conductor Diameter: - mm
  • Neutral Conductor Diameter: - mm
  • Average insulation thickness: 0.9 mm
  • Insulation thickness of neutral conductor: - mm
  • Average sheath thickness: 1.3 mm
  • Nominal outer diameter: 11.6 mm
  • Nominal overall diameter of each phase cable: - mm
  • Nominal overall diameter: - mm
  • Approximate weight: 140 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
  • Permissible short circuit current conductor 1s: 2.3 kA

 

ARE4E 0,6/1kV 1x50 IT

Nexans ref. 10548240

  • With smaller neutral conductor: No
  • Neutral Type:
  • Lay Up: Single core
  • Number of cores: 1
  • Number of phases: -
  • Conductor cross-section: 50 mm²
  • Phase Conductor Cross Section: - mm²
  • Neutral conductor section (when smaller): - mm²
  • Conductor diameter: 8.2 mm
  • Phase Conductor Diameter: - mm
  • Neutral Conductor Diameter: - mm
  • Average insulation thickness: 1.0 mm
  • Insulation thickness of neutral conductor: - mm
  • Average sheath thickness: 1.3 mm
  • Nominal outer diameter: 14.1 mm
  • Nominal overall diameter of each phase cable: - mm
  • Nominal overall diameter: - mm
  • Approximate weight: 220 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
  • Permissible short circuit current conductor 1s: 4.7 kA

 

ARE4E 0,6/1kV 1x95 IT

Nexans ref. 10548242

  • With smaller neutral conductor: No
  • Neutral Type:
  • Lay Up: Single core
  • Number of cores: 1
  • Number of phases: -
  • Conductor cross-section: 95 mm²
  • Phase Conductor Cross Section: - mm²
  • Neutral conductor section (when smaller): - mm²
  • Conductor diameter: 11.5 mm
  • Phase Conductor Diameter: - mm
  • Neutral Conductor Diameter: - mm
  • Average insulation thickness: 1.1 mm
  • Insulation thickness of neutral conductor: - mm
  • Average sheath thickness: 1.4 mm
  • Nominal outer diameter: 18.0 mm
  • Nominal overall diameter of each phase cable: - mm
  • Nominal overall diameter: - mm
  • Approximate weight: 380 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
  • Permissible short circuit current conductor 1s: 8.9 kA

 

ARE4EX 0,6/1kV 3x150+95N IT

Nexans ref. 10548249

  • With smaller neutral conductor: Yes
  • Neutral Type: Aluminium - Class 2 acc. to IEC 60228
  • Lay Up: Twisted single cores
  • Number of cores: 4
  • Number of phases: 3
  • Conductor cross-section: - mm²
  • Phase Conductor Cross Section: 150 mm²
  • Neutral conductor section (when smaller): 95 mm²
  • Conductor diameter: - mm
  • Phase Conductor Diameter: 14.3 mm
  • Neutral Conductor Diameter: 11.5 mm
  • Average insulation thickness: 1.4 mm
  • Insulation thickness of neutral conductor: 1.10 mm
  • Average sheath thickness: 1.4 mm
  • Nominal outer diameter: - mm
  • Nominal overall diameter of each phase cable: 21.6 mm
  • Nominal overall diameter: 50.0 mm
  • Approximate weight: 2040 kg/km
  • Max. DC resistance of the conductor at 20°C: - Ohm/km
  • Permissible short circuit current conductor 1s: - kA

 

ARE4EX 0,6/1kV 3x240+150N IT

Nexans ref. 10547934

  • With smaller neutral conductor: Yes
  • Neutral Type: Aluminium - Class 2 acc. to IEC 60228
  • Lay Up: Twisted single cores
  • Number of cores: 4
  • Number of phases: 3
  • Conductor cross-section: - mm²
  • Phase Conductor Cross Section: 240 mm²
  • Neutral conductor section (when smaller): 150 mm²
  • Conductor diameter: - mm
  • Phase Conductor Diameter: 18.5 mm
  • Neutral Conductor Diameter: 14.3 mm
  • Average insulation thickness: 1.7 mm
  • Insulation thickness of neutral conductor: 1.40 mm
  • Average sheath thickness: 1.5 mm
  • Nominal outer diameter: - mm
  • Nominal overall diameter of each phase cable: 26.9 mm
  • Nominal overall diameter: 61.7 mm
  • Approximate weight: 3200 kg/km
  • Max. DC resistance of the conductor at 20°C: - Ohm/km
  • Permissible short circuit current conductor 1s: - kA

 

Description

Description

Standards

  • National
    GSC002

Single core and helically bundled tetra polar cables with aluminium conductor, XLPE insulation, polyolefin outer sheath.

Cables compliant with the requirements of the Construction Products Regulation “CPR (EU) n° 305/2011”.

Fire performance class:  Eca

Application:

Suitable for fixed installation laying indirectly buried.

Construction:

  • Conductor: stranded, compacted, round aluminium – Cl. 2 (CEI EN 60228).
  • Insulation: extruded polyethylene (XLPE) compound.
  • Outer sheath: extruded polyolefin (PO) compound. Colour: black.

Functional characteristics:

  • Rated voltages U0/U: 0,6/1 kV
  • Max. operating temperature of conductor: 90°C
  • Max. short circuit temperature of conductor: 250°C (max 5s)
  • Min. installation temperature: -25°C
  • Max. tensile strength on the conductor during installation: 50 N/mm2
  • Min. bending radius during installation (single core cables): 6 Dcable
  • Min. bending radius during installation (quadripolar cables): 9 Dphase

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor shape
Round, stranded and compacted
Conductor flexibility
Class 2 acc. to IEC 60228
Insulation
Extruded XLPE compound
Insulation colour
Natural
Outer sheath
Extruded polyolefin-based thermoplastic compound
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Sheath thickness of the neutral conductor
1.40 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close