ARE4*E4*X(*) 0,6/1kV INRETE / Fca

Products

ARE4*E4*X 0,6/1kV 2x16

Nexans ref. 10579440

  • Conductor shape: Round, stranded and not compacted
  • Messenger: No
  • Messenger shape:
  • Messenger flexibility:
  • Number of cores: 2
  • Number of phases: 1
  • Phase Conductor Cross Section: 16 mm²
  • Messenger cross-section: - mm²
  • Phase Conductor Diameter: 4.9 mm
  • Messenger conductor diameter: - mm
  • Average insulation thickness: 1.3 mm
  • Messenger insulation thickness: - mm
  • Nominal overall diameter of each phase cable: 8.4 mm
  • Overall messenger diameter: - mm
  • Nominal overall diameter: 16.8 mm
  • Approximate weight: 160 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
  • Permissible short circuit current conductor 1s: 1.6 kA

 

ARE4*E4*X 0,6/1kV 4x16

Nexans ref. 10579441

  • Conductor shape: Round, stranded and not compacted
  • Messenger: No
  • Messenger shape:
  • Messenger flexibility:
  • Number of cores: 4
  • Number of phases: 3
  • Phase Conductor Cross Section: 16 mm²
  • Messenger cross-section: - mm²
  • Phase Conductor Diameter: 4.9 mm
  • Messenger conductor diameter: - mm
  • Average insulation thickness: 1.3 mm
  • Messenger insulation thickness: - mm
  • Nominal overall diameter of each phase cable: 8.4 mm
  • Overall messenger diameter: - mm
  • Nominal overall diameter: 20.0 mm
  • Approximate weight: 310 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
  • Permissible short circuit current conductor 1s: 1.6 kA

 

ARE4*E4*X* 0,6/1kV 3x35+54,6

Nexans ref. 10579442

  • Conductor shape: Round, stranded and compacted
  • Messenger: Aluminium alloy
  • Messenger shape: Round, stranded and not compacted
  • Messenger flexibility: Class 2 acc. to IEC 60228
  • Number of cores: 4
  • Number of phases: 3
  • Phase Conductor Cross Section: 35 mm²
  • Messenger cross-section: 54.6 mm²
  • Phase Conductor Diameter: 7 mm
  • Messenger conductor diameter: 9.5 mm
  • Average insulation thickness: 1.6 mm
  • Messenger insulation thickness: 1.6 mm
  • Nominal overall diameter of each phase cable: 11.1 mm
  • Overall messenger diameter: 13 mm
  • Nominal overall diameter: 29.3 mm
  • Approximate weight: 660 kg/km
  • Max. DC resistance of the conductor at 20°C: - Ohm/km
  • Permissible short circuit current conductor 1s: - kA

 

ARE4*E4*X* 0,6/1kV 3x70+54,6

Nexans ref. 10579443

  • Conductor shape: Round, stranded and compacted
  • Messenger: Aluminium alloy
  • Messenger shape: Round, stranded and not compacted
  • Messenger flexibility: Class 2 acc. to IEC 60228
  • Number of cores: 4
  • Number of phases: 3
  • Phase Conductor Cross Section: 70 mm²
  • Messenger cross-section: 54.6 mm²
  • Phase Conductor Diameter: 9.8 mm
  • Messenger conductor diameter: 9.5 mm
  • Average insulation thickness: 1.6 mm
  • Messenger insulation thickness: 1.6 mm
  • Nominal overall diameter of each phase cable: 13.9 mm
  • Overall messenger diameter: 13 mm
  • Nominal overall diameter: 34.7 mm
  • Approximate weight: 970 kg/km
  • Max. DC resistance of the conductor at 20°C: - Ohm/km
  • Permissible short circuit current conductor 1s: - kA

 

Description

Description

Standards

  • International
    HD 626; IEC 60502-1

Helically bundled multipolar cables, with or without neutral messenger. Phases with aluminium conductor, XLPE insulation, XLPE outer sheath. Neutral messenger with aluminium alloy conductor, XLPE insulation.

Cables compliant with the requirements of the Construction Products Regulation “CPR (EU) n° 305/2011”.

Fire performance class:  Fca

Application:

Suitable for fixed installation laying in air.

Construction:

  • Conductor (phase): stranded, not compacted, round aluminium – Cl. 2 (IEC 60228) (16 mm2);
  • Conductor (phase): stranded, compacted, round aluminium – Cl. 2 (IEC 60228) (35 mm2, 70 mm2).
  • Insulation (phase): extruded polyethylene (XLPE) compound. Colour: black. 
  • Outer sheath (phase): extruded polyethylene (XLPE) compound. Colour: grey.
  • Conductor (neutral): stranded, not compacted, round aluminium alloy – Cl. 2 (IEC 60228).
  • Insulation (neutral): extruded polyethylene (XLPE) compound. Colour: grey.

Functional characteristics:

  • Rated voltages U0/U: 0,6/1 kV
  • Max. operating temperature of conductor (phase): 90°C
  • Max. short circuit temperature of conductor (phase): 250°C (max 5s)
  • Min. installation temperature: -25°C
  • Max. tensile strength on the conductor during installation: 50 N/mm2
  • Min. bending radius during installation: 9 Dphase

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor flexibility
Class 2 acc. to IEC 60228
Insulation
Extruded XLPE
Insulation colour
Black
Lay Up
Twisted single cores
Outer sheath
Extruded XLPE
Sheath colour
Grey

Dimensional characteristics

Dimensional characteristics

Average sheath thickness
0.2 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close