- Markets
- Products
- Newsroom
- About Nexans
- Tools & Resources
- Search
- Contact us
- Compare
- Sign in
ARE4*E4*X(*) 0,6/1kV / Fca
ARE4*E4*X 0,6/1kV 2x16 IT
Nexans ref. 10548232
- Conductor shape: Round, stranded and not compacted
- Messenger: No
- Messenger shape:
- Messenger flexibility:
- Number of cores: 2
- Number of phases: 1
- Phase Conductor Cross Section: 16 mm²
- Messenger cross-section: - mm²
- Phase Conductor Diameter: 4.9 mm
- Messenger conductor diameter: - mm
- Average insulation thickness: 1.3 mm
- Messenger insulation thickness: - mm
- Nominal overall diameter of each phase cable: 8.4 mm
- Overall messenger diameter: - mm
- Nominal overall diameter: 16.8 mm
- Approximate weight: 160 kg/km
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible short circuit current conductor 1s: 1.6 kA
ARE4*E4*X 0,6/1kV 4x16 IT
Nexans ref. 10547961
- Conductor shape: Round, stranded and not compacted
- Messenger: No
- Messenger shape:
- Messenger flexibility:
- Number of cores: 4
- Number of phases: 3
- Phase Conductor Cross Section: 16 mm²
- Messenger cross-section: - mm²
- Phase Conductor Diameter: 4.9 mm
- Messenger conductor diameter: - mm
- Average insulation thickness: 1.3 mm
- Messenger insulation thickness: - mm
- Nominal overall diameter of each phase cable: 8.4 mm
- Overall messenger diameter: - mm
- Nominal overall diameter: 20.0 mm
- Approximate weight: 310 kg/km
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible short circuit current conductor 1s: 1.6 kA
ARE4*E4*X* 0,6/1kV 3x35+54,6 IT
Nexans ref. 10547959
- Conductor shape: Round, stranded and compacted
- Messenger: Aluminium alloy
- Messenger shape: Round, stranded and not compacted
- Messenger flexibility: According to GSCC009
- Number of cores: 4
- Number of phases: 3
- Phase Conductor Cross Section: 35 mm²
- Messenger cross-section: 54.6 mm²
- Phase Conductor Diameter: 7 mm
- Messenger conductor diameter: 9.5 mm
- Average insulation thickness: 1.6 mm
- Messenger insulation thickness: 1.6 mm
- Nominal overall diameter of each phase cable: 11.1 mm
- Overall messenger diameter: 13 mm
- Nominal overall diameter: 29.3 mm
- Approximate weight: 660 kg/km
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible short circuit current conductor 1s: - kA
ARE4*E4*X* 0,6/1kV 3x70+54,6 IT
Nexans ref. 10548012
- Conductor shape: Round, stranded and compacted
- Messenger: Aluminium alloy
- Messenger shape: Round, stranded and not compacted
- Messenger flexibility: According to GSCC009
- Number of cores: 4
- Number of phases: 3
- Phase Conductor Cross Section: 70 mm²
- Messenger cross-section: 54.6 mm²
- Phase Conductor Diameter: 9.8 mm
- Messenger conductor diameter: 9.5 mm
- Average insulation thickness: 1.6 mm
- Messenger insulation thickness: 1.6 mm
- Nominal overall diameter of each phase cable: 13.9 mm
- Overall messenger diameter: 13 mm
- Nominal overall diameter: 34.7 mm
- Approximate weight: 970 kg/km
- Max. DC resistance of the conductor at 20°C: - Ohm/km
- Permissible short circuit current conductor 1s: - kA
Description
Description
Standards
- 
                                            ProductGSCC009
Description
Helically bundled multipolar cables, with or without neutral messenger. Phases with aluminium conductor, XLPE insulation, XLPE outer sheath. Neutral messenger with aluminium alloy conductor, XLPE insulation.
Cables compliant with the requirements of the Construction Products Regulation “CPR (EU) n° 305/2011”.
Fire performance class: Fca
Application:
Suitable for fixed installation laying in air.
Construction
- Conductor (phase): stranded, not compacted, round aluminium – Cl. 2 (CEI EN 60228) (16 mm2);
- Conductor (phase): stranded, compacted, round aluminium – Cl. 2 (CEI EN 60228) (35 mm2, 70 mm2).
- Insulation (phase): extruded polyethylene (XLPE) compound. Colour: black.
- Outer sheath (phase): extruded polyethylene (XLPE) compound. Colour: grey.
- Conductor (neutral): stranded, not compacted, round aluminium alloy (GSCC009).
- Insulation (neutral): extruded polyethylene (XLPE) compound. Colour: grey.
Functional characteristics
- Rated voltages U0/U: 0,6/1 kV
- Max. operating temperature of conductor (phase): 90°C
- Max. short circuit temperature of conductor (phase): 250°C (max 5s)
- Min. installation temperature: -25°C
- Max. tensile strength on the conductor during installation: 50 N/mm2
- Min. bending radius during installation: 9 Dphase
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                            Conductor material
                                                        
                                                        
                                                            Aluminum 
                                                        
                                                    
                                                            Conductor flexibility
                                                        
                                                        
                                                            Class 2 acc. to IEC 60228 
                                                        
                                                    
                                                            Insulation
                                                        
                                                        
                                                            Extruded XLPE compound 
                                                        
                                                    
                                                            Insulation colour
                                                        
                                                        
                                                            Black 
                                                        
                                                    
                                                            Lay Up
                                                        
                                                        
                                                            Twisted single cores 
                                                        
                                                    
                                                            Outer sheath
                                                        
                                                        
                                                            Extruded XLPE 
                                                        
                                                    
                                                            Sheath colour
                                                        
                                                        
                                                            Grey 
                                                        
                                                    Dimensional characteristics
Dimensional characteristics
                                                            Average sheath thickness
                                                        
                                                        
                                                            0.2 mm
                                                        
                                                    Electrical characteristics
Electrical characteristics
                                                            Rated Voltage Uo/U (Um)
                                                        
                                                        
                                                            0.6/ 1 (1.2) kV 
                                                        
                                                    Resources