Nexans PV AC/DC 1x500

Description

Description

Standards

  • Product
    EN 50575; EN 60529; IEC 60228; IEC 60502-1
  • Test
    HD 605

Applications

The PV AC/DC cable is designed for energy installations requiring performance and reliability:

  • Photovoltaic installations (solar plants, rooftops, infrastructures)
  • Installation in open air, on cable trays or indirectly buried
  • Outdoor environments and humid areas (AD7)
  • 1.8/3 kV according to IEC 60502-1 dielectric test, based on IMQ test report No. CN26-0132320.02

Key advantages

  • XLPE insulation: excellent thermal resistance up to 90 °C in operation
  • High short-circuit resistance (up to 250 °C)
  • UV-resistant PVC sheath for outdoor applications
  • Suitable for humid environments (AD7) (IEC 60364-5-51)
  • Compliant with IEC standards (IEC 60502-1)

By choosing the PV AC/DC cable, you opt for a high-performance, reliable and durable solution, perfectly suited for demanding photovoltaic installations and outdoor environments.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class 2 acc. to IEC 60228
Conductor material
Aluminum
Conductor shape
Compact round
Halogen free
No
Insulation
XLPE
Number of conductors
1
Outer sheath
PVC
Sheath colour
Black
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Approximate weight
1814 kg/km
Average insulation thickness
2.2 mm
Conductor cross-section
500 mm²
Conductor diameter
26.7 mm
Diameter over insulation
31.1 mm
Neutral conductor section (when smaller)
- mm²
Nominal outer diameter
35.1 mm
Nominal outer sheath thickness
2.0 mm

Electrical characteristics

Electrical characteristics

Impedance at 50Hz and 90°C
0.08 Ohm/km
Max. DC resistance of the conductor at 20°C
0.0605 Ohm/km
Perm. current rating buried 20°C - trefoil formation
644 A
Perm. current rating in air 30°C - trefoil formation
761 A
Permissible short circuit current conductor 1s
47.2 kA
Rated Voltage Uo/U
1.5/1.5 kV DC – 1/1 kV AC
Rated Voltage Uo/U (Um)
1,5/1,5 (1,8) kV CC - 1,0/1,0 (1,2) kV CA

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1
Max. conductor temperature in service
90 °C
Maximum operating temperature
- °C
Minimum installation temperature
- °C
Operating temperature, range
-25 ... 60 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close