INTERBUS HYBRID PUR CABLES

Description
Interbus cable with PUR jacket for dynamic applications, shielded, oil resistant, flame retardant

Description
Standards
International : UL and CSA approvalDescription
Applications
Interbus cables connect sensors and actors with all standard equipment in automation.
Our product range fulfill the special requirement of:
- Standard for fix installation or few bending
- For use in chain
- HFFR (Halogen Free & Flame Retardant)
- Direct burial
- Food industry
- Marine and submarine
- Railway systems
Design
Insulation colour code
Section 0.25 mm²: DIN 47100
Section 1 mm²: Blue - Red - Green/yellow
D.C. Resistance
Section 0.25 mm²: 80 Ohm/km
Section 1 mm²: 19.5 Ohm/km
Insulation resistance
Section 0.25 mm²: 5000 MOhm/km
Section 1 mm²: 5 MOhm/km
Normative references
UL recognized / CSA approval
AWM 80°C-30V
AWM 75°C-30V FT1
Characteristics
Construction characteristics | |
---|---|
Construction type | (3x2x0,25+3G1)C |
Conductor material | Bare copper |
Insulation | Polyolefin |
Insulation colour | DIN 47100 |
Material of filler / inner sheath | Textile |
Taping | Non woven tape |
Shielding | ≥85% tinned copper braid coverage |
Separator | Non woven tape |
Outer sheath | PUR |
Sheath colour | Violet RAL 4001 |
Dimensional characteristics | |
Nominal outer diameter | 8.2mm |
Copper content | 50kg/km |
Approximate weight | 105kg/km |
Electrical characteristics | |
Rated Voltage Uo/U | 30 V |
Characteristic impedance | 100Ohm |
Test voltage | 1500V |
Transmission characteristics | |
Attenuation at 256 kHz | 1.5dB/100m |
Attenuation at 722 kHz | 2.4dB/100m |
Attenuation at 1 Mhz | 2.7dB/100m |
Attenuation at 4 MHz | 5.2dB/100m |
Attenuation at 10 MHz | 8.4dB/100m |
Attenuation at 16 MHz | 11.2dB/100m |
Attenuation at 20 MHz | 11.9dB/100m |
Near End Cross Talk @ 722 kHz | 61dB/100m |
Near End Cross Talk @ 1 MHz | 59dB/100m |
Near End Cross Talk @ 2 MHz | 55dB/100m |
Near End Cross Talk @ 4 MHz | 50dB/100m |
Near End Cross Talk @ 8 MHz | 46dB/100m |
Near End Cross Talk @ 10 MHz | 44dB/100m |
Near End Cross Talk @ 16 MHz | 41dB/100m |
Near End Cross Talk @ 20 MHz | 40dB/100m |
Nominal Velocity of Propagation (NVP) | 66% |
Mechanical characteristics | |
Bending cycles | 5.0Mio. |
Maximum acceleration | 20m/s² |
Speed | 240 m/min |
Usage characteristics | |
Field of application | Dynamic |
Minimum dynamic operating bending radius | 10(xD) |
Operating temperature, range | -20 .. 80°C |
Storage temperature, range | -30 .. 80°C |
Oil resistance | EN 50363-10-2 |
Flame retardant | IEC 60332-1-2; FT1; UL 1581; EN 50265-2-1 |