italiano Login Get Registered Catalog Browser Contact Us
Global expert in cables and cabling system

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

EN 50264-2-1 - Single core

Send link to this page print Your Nexans contact on this page
EN 50264-2-1 - Single core Flexible single core cables
from 1 to 400mm²
Conductor temperature:90°C
Standards
International  EN 45545-1; EN 50264-1; EN 50265-2-1; EN 50266-2-4; EN 50267-2-1; EN 50267-2-2; EN 50268-2
Description

Applications

Railways vehicules (locomotives, trains, trolley-busses, etc..) and installations.

 

Particular properties

  • Halogen free.
  • High resistance at very low temperature
  • Very high resistance at oils and fuels
  • Flame retardant
  • Fire retardant
  • Low smoke emission and opacity

 

Construction

  1. Conductor
    Flexible stranded tinned copper class 5 according to EN 60228
     
  2. Separator tape
    (for conductors size 10-400mm²)
     
  3. Insulation
    Type EI 104: Cross-linked halogen free rubber
     

Marking on the outer sheath

Nexans "factory code" EN50264-2 "voltage rating Uo" "conductor size"  "hazard level EN 45545-1 " (M means extra low temperature  /extra oil fuel resistance)

Example for cable 0,6!1 kV 1x6 mm2
NEXANS B EN 50264-2-1 600 V 6 M

 

Minimum Bending radius

  • Dynamic use: 5 +8 times the outer diameter
  • Static use: 4 times the outer diameter

 

Colour code: Standard colour of insulation : black
 

Standards

  • EN 50264-1: General requirement
  • EN 50264-2: Design and test
  • EN 45555-1: Fire protection
  • EN 50265-2-1: Flame propagation
  • EN 50265-2-4: Fire propagation
  • EN 50267-2-1: Halogen acide gas
  • EN 50267-2-2: Acidity of gases
  • EN 50268-3: Smoke density

 TOP
Characteristics
Construction characteristics
Conductor material Tinned copper  
Insulation Cross-linked halogen free rubber  
Halogen free IEC 60754-1  
Dimensional characteristics
Number of cores 1  
Electrical characteristics
Rated Voltage Uo/U (Um) 0.6/1 kV  
Mechanical characteristics
Cable flexibility Flexible  
Mechanical resistance to impacts Good  
Usage characteristics
Fire retardant UNE-EN 50266-2-4  
Smoke density EN 50268-2  
Max. conductor temperature in service 90°C  
Flame retardant EN 50265-2-1  
Oil resistance Oil and fuel resistance  
Gases toxicity EN 50267-2-1 & 2-2  

 TOP
Results   18/18
Select all Items Nexans ref. Name Cross section (mm²) Min. outer diam. (mm) Max. outer diam. (mm) Approx. weight (kg/km)
Make to order product EN 50264-2-1 1x1.0 mm² 1 2.9 3.2 17
Make to order product EN 50264-2-1 1x1.5 mm² 1.5 3.1 3.5 21
Make to order product EN 50264-2-1 1x2.5 mm² 2.5 3.6 3.9 31
Make to order product EN 50264-2-1 1x4 mm² 4 4.1 4.6 46
Make to order product EN 50264-2-1 1x6 mm² 6 4.8 5.4 66
Make to order product EN 50264-2-1 1x10 mm² 10 6.5 6.8 113
Make to order product EN 50264-2-1 1x16 mm² 16 7.6 8.5 165
Make to order product EN 50264-2-1 1x25 mm² 25 8.9 10.0 248
Make to order product EN 50264-2-1 1x35 mm² 35 10.0 11.5 344
Make to order product EN 50264-2-1 1x50 mm² 50 11.9 13.5 483
Make to order product EN 50264-2-1 1x70 mm² 70 13.5 15.5 665
Make to order product EN 50264-2-1 1x95 mm² 95 15.1 17.4 883
Make to order product EN 50264-2-1 1x120 mm² 120 16.7 19.3 1102
Make to order product EN 50264-2-1 1x150 mm² 150 18.7 21.7 1379
Make to order product EN 50264-2-1 1x185 mm² 185 20.7 23.6 1676
Make to order product EN 50264-2-1 1x240 mm² 240 23.8 26.8 2191
Make to order product EN 50264-2-1 1x300 mm² 300 26.4 29.7 2767
Make to order product EN 50264-2-1 1x400 mm² 400 29.4 33.6 3544
Add to favorites

 TOP
Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map